The 3 effect modules
Resonant filter bank (Fixed Filter bank): affects equalization to the outgoing signal
coming from the 2 output amplifiers in function with the state of the interrupters
“VCA1” and “VCA2”. This equalization is done with the help of resonant filters with 12
band-pass filters; each of the bands has a level (positive or negative) and bandwidth
setting. This module also possesses a low-pass filter (80 Hz) and a fixed high-pass (12
kHz).
Chorus: the chorus module allows a frequency modulation where the rapidity can be
set with the rotating “rate” button, the amplitude with the rotating “amount” button,
and the width by the rotating “delay” button.
Stereo delay (Dual Delay): allows the repetition of the incoming signal independently
for the left and right, which explains the presence of 2 control columns, one for each
side.
5.4.2.1 The fixed filter bank
The fixed filter bank